competent technicians and tenders ...


Consult regularly with public tenders of the various agencies that recruit engineering services for activities that promote attitudes one finds that, at least, can be considered as unusual. We summarize the final. The
ITACyL , Agrarian Technological Institute, an autonomous agency of the Ministry of Agriculture and Livestock of the Junta de Castilla y León, tendered a few months ago services for Coordination on Safety and Health in the works dependent ITACyL for the various provinces of the Autonomous Community.
already in the bidding phase had to modify the Bid, well, nine contests for the nine provinces ... as a senior engineer is required to perform the service. Someone advised to amend the wording, asking a competent technician with training in risk prevention. (I do not think it is worth deepening the term Engineer .... Do not know any English university, public or private or issue such title)
Well, at the time resolve the contest can be viewed as in resolutions are excluded propositions in which technicians were given the title of Mining Engineer, Technical Architect or Engineer Industrial, claiming according to the report of the sub file promoter March 24, 2010 (¿?¿?¿?) these qualifications do not enable to perform the duties of coordinator of safety and health in civil engineering. And they are so wide.
ITACyL Who is the authority to assign professional technician or another? Is hiring a Site Manager or Safety and Health Coordinator? Just going to do civil works content? Reviewing
works promoted by the agency in past years can see how some of them involve the laying of GRP pipes for irrigation networks, construction of industrial buildings to house stations pumping centers to transformers to supply power to these pumping stations, control facilities, etc ... I hesitate to assign a percentage of civil engineering to such achievements. According
Judgement No 116/10 of the Court of Administrative Litigation No. 2 Jaen, the role of coordinator of safety and health ... sticks to ensure compliance with safety standards, not to organize up any development order or building activity ... as the basis contemplated in the Law of Construction Planning, which regulates what professionals can do coordinating role in safety and health can Architects, Technical Architects, Engineers and Technical Engineers .

Dental Titanium Grill

New visa requirements for professional work New



The Government has released draft Royal Decree on visa requirements collegial professional jobs. It opened at a time within 15 days, starting on May 3, to move any arguments to the text of the draft royal decree on visa requirements collegiate and professional work Memory Regulatory Impact Analysis.


A reading of the draft follows that from the date of publication and entry into force of the Decree the only jobs that will need to endorse are:

• Projects, certificates and final building work.

• Projects building demolition without explosives.

• special blasting projects.

• Draft commercial warehouses and factories and use of explosives.

• Project workshops of cartridge and fireworks.

• Projects exploitation of mineral resources.

• Projects common telecommunication infrastructure.

The election of these projects will need visa college for processing, according to the draft, we used a double test based on the necessity and proportionality. That is, we evaluated the existence of a direct causal link between the completion of concrete work and the effect on the physical integrity or safety of persons, and studied if the visa is the instrument of control provided from the possible.

which is not I doubt that the projects chosen for visas require effective monitoring to ensure that the content they conform to current regulations and to safeguard the safety of persons or users of the actions arising from the work technical. But

I dare to question the inclusion of other work in this regard. For example:

High Voltage Installations. I think it's clear the relationship between the proper wording of l project with the safety of persons and property affected by power lines.

• Low voltage electrical installations . Electrical installations in our homes, bars and restaurants we frequent, the factories in which we work or our children's schools will not have a visa project because it seems that the bad performance of the same will not result dangerous situations for users .... as the editor of the draft Royal Decree ...

• Heating and Plumbing . Since the entry into force of the Decree the boilers we have in our buildings, or in our kitchen, and have not required a revised draft by the professional. (Do not forget that the boilers are pressure vessels ...)

• Gas Facilities and other fuels.


• Service stations.


• street lighting facilities.


• Centers of transformation.


• Tower cranes.


• Reforms of vehicles.


• Storage of flammable and combustible liquids.


• Compressed air systems.


• Refrigeration.


• fire protection facilities.

sure this whole relationship, not exhaustive, list of facilities soon will not need visa to be processed, all could find reason to believe that inadequate design and implementation of the work could lead to significant risks for people and for equipment and facilities.
All but the lawmaker responsible for drafting the draft royal decree, which seems to find more danger in the installation of coaxial cable that brings us to our television signal receiver in electrical installation of our building that can have powers of hundreds of watts of power .... The